Smoke removal fans NED VDKN DU, VDKV DU, VDKV2x DU, etc

Roof fans with air ejection to the sides of the VDKN DU are designed to move smoke-air mixtures with a temperature of 400 °C or 600 ° C during a fire for 2 hours.
- 14 standard sizes with a capacity from 2,300 m3/h to 140,000 m3/h and a static pressure of up to 2,100 Pa.
- Roof fans with air ejection to the sides. Technical specifications
Roof fans with flare air VDKN DU are designed to move smoke-air mixtures with a temperature of 400 °C or 600 °C during a fire for 2 hours.
- 14 standard sizes with a capacity from 2,300 m3/h to 130,000 m3/h and a static pressure of up to 2,100 Pa.
- VDKN-AF-3.15DU-00; VDKN-AF-3.55DU-00; VDKN-AF-4DU-00; VDKN-AF-4.5DU-00; VDKN-AF-5DU-00, etc.
- VDKN-BF-3.15DU-00; VDKN-BF-3.55DU-00; VDKN-BF-4DU-00; VDKN-BF-4.5DU-00; VDKN-BF-5DU-00; VDKN-BF-5.6DU-00; VDKN-BF-6.3DU-00 and others .
- VDKN-CF-7,1DU-00; VDKN-CF-8DU-00; VDKN-CF-8DU-01; VDKN-CF-11,2DU-00, etc.
VDKV DU roof fans are designed to move smoke-air mixtures with a temperature of 400°C or 600°C during a fire for 2 hours.
- 11 standard sizes with a capacity from 3,000 m3/h to 47,000 m3/h and a static pressure of up to 2,000 Pa.
Models: VDKV-2.5DU; VDKV-2.8DU; VDKV-3.15DU; VDKV-3.55DU; VDKV-4DU; VDKV-4.5DU; VDKV-5DU; VDKV-5.6DU; VDKV-6.3DU; VDKV-7.1DU; VDKV-8DU
VDKV2x DU roof-mounted dual smoke removal fans are designed to move smoke-air mixtures with a temperature of 400°C or 600°C during a fire for 2 hours.
- 11 standard sizes with a capacity from 6,000 m3/h to 90,000 m3/h and a static pressure of up to 2,000 Pa.
Models: VDKV2x-2,5DU; VDKV2x-5DU; VDKV2x-5,6DU; VDKV2x-6,ZDU; VDKV2x-7,1DU; VDKV2x-8DU
VODK DU roof axial smoke removal fans are designed to move smoke-air mixtures with a temperature of 400°C or 600°C during a fire for 2 hours.
- 7 standard sizes with a capacity from 500 m3/h to 120,000 m3/h and a static pressure of up to 570 Pa.
Models: VODK-21-210KB-4DU-4; VODK-21-210KA-5DU-4; VODK-21-210KB-5DU-4; VODK-21-210KA-6,ZDU-4; VODK-21-210KB-6,ZDU-4; VODK-21-210KA-8DU-4; VODK-21-210KB-8DU-4; VODK-21-210KA-10DU-6; VODK-21-210KB-10DU-6, etc.
Axial VOD DU smoke removal fans are designed to move smoke-air mixtures with a temperature of 400 °C or 600 °C during a fire for 2 hours.
- 7 standard sizes with a capacity from 500 m3/h to 120,000 m3/h and a static pressure of up to 610 Pa.
Models: VOD-21-210B-4DU-4; VOD-21-210A-5DU-4; VOD-21-210B-5DU-4; VOD-21-210A-6.3DU-4; VOD-21-210B-6.3DU-4; VOD-21-210A-8DU-4; VOD-21-210B-8DU-4, etc.
VDS DU wall-mounted smoke removal fans are designed to move smoke-air mixtures with a temperature of 400°C or 600°C during a fire for 2 hours.
- 9 standard sizes with a capacity from 1000 m3/h to 49000 m3/h and a static pressure of up to 1,600 Pa.
Models: VDS-A/B-3.15DU-4; VDS-A/B-3.55DU-4; VDS-A/B-4DU-4; VDS-A/B-4.5DU-4; VDS-A/B-5DU-4; VDS-A/B-5.6DU-4; VDS-A/B-6.3DU-6; VDS-A/B-6.3DU-4; VDS-A/B-7.1DU-6; VDS-A/B-7.1DU-4; VDS-A-8DU-8; VDS-A/B-8DU-6; VDS-A/B-8DU-4
VRD 80-70 DU radial smoke removal fans are designed to move smoke-air mixtures with a temperature of 400 °C or 600 °C during a fire for 2 hours.
- 8 standard sizes with a capacity from 500 m3/h to 65,000 m3/h and a static pressure of up to 1,600 Pa.
Models: VRD-80-70-2,5 DU; VRD-80-70-3,15 DU; VRD-80-70- 4DU; VRD-80-70- 5DU; VRD-80-70-6,3 DU; VRD-80-70- 8DU; VRD-80-70- 10DU; VRD-80-70-12,5 DU
Radial smoke removal fans VRD 280-46 DU are designed to move smoke-air mixtures with a temperature of 400 ° C or 600 °C during a fire for 2 hours.
- 6 standard sizes with a capacity from 2000 m3/h to 42000 m3/h and a static pressure of up to 3000 Pa.
Models: VRD-280-46-2,5 DU; VRD-280-46-3,15 DU; VRD-280-46- 4DU; VRD-280-46- 5DU; VRD-280-46-6,3 DU; VRD-280-46- 8DU
All NED products
About NED
-
HIGH TECH RELIGIONS
Modern design, based on world experience and international standards. Automated design process using 3D models. Materials and components of the highest class. -
COMPREHENSIVE SOLUTIONS
Thanks to an extensive range, NED equipment allows you to solve any engineering problem for ventilation and cold supply of premises. More than 7000 items of products are produced under the NED brand. -
MARKET LEADER
The NED brand has been actively conquering the domestic market of climate systems since 2002. The best engineering solutions for ventilation and air conditioning on the market.
NEW TECHNOLOGIES GROUP
Contact us or your local dealer for more information on certifications, features, reviews, pricing, stock availability and delivery terms for NED products.
Reply guaranteed within 8 business hours
- (727)345-47-04
- (3955)60-70-56
- (8182)63-90-72
- (8512)99-46-04
- (3852)73-04-60
- (4722)40-23-64
- (4162)22-76-07
- (4832)59-03-52
- (8352)28-53-07
- (351)202-03-61
- (8202)49-02-64
- (3022)38-34-83
- (395)279-98-46
- (4932)77-34-06
- (3412)26-03-58
- (4012)72-03-81
- (4842)92-23-67
- (843)206-01-48
- (3842)65-04-62
- (4212)92-98-04
- (8332)68-02-04
- (4966)23-41-49
- (4942)77-07-48
- (861)203-40-90
- (391)204-63-61
- (3522)50-90-47
- (4712)77-13-04
- (4742)52-20-81
- (3519)55-03-13
- (375)257-127-884
- (495)268-04-70
- (8152)59-64-93
- (8552)20-53-41
- (831)429-08-12
- (3843)20-46-81
- (383)227-86-73
- (3496)41-32-12
- (3812)21-46-40
- (4862)44-53-42
- (3532)37-68-04
- (8412)22-31-16
- (342)205-81-47
- (8142)55-98-37
- (8112)59-10-37
- (863)308-18-15
- (4912)46-61-64
- (812)309-46-40
- (846)206-03-16
- (8342)22-96-24
- (845)249-38-78
- (8692)22-31-93
- (3652)67-13-56
- (4812)29-41-54
- (862)225-72-31
- (8652)20-65-13
- (3462)77-98-35
- (8212)25-95-17
- (4752)50-40-97
- (998)71-205-18-59
- (8482)63-91-07
- (3822)98-41-53
- (4872)33-79-87
- (4822)63-31-35
- (3452)66-21-18
- (347)229-48-12
- (3012)59-97-51
- (8422)24-23-59
- (8672)28-90-48
- (4922)49-43-18
- (423)249-28-31
- (844)278-03-48
- (8172)26-41-59
- (473)204-51-73
- (4112)23-90-97
- (4852)69-52-93
- (343)384-55-89